19
The lower the IPO frequency, the less current the ZAURA RF Wireless
Module will consume. However, it will also be more difficult to keep pace
with a peer device running at a higher IPO frequency and sending bursts
of data. Zilog recommends operating peer devices at the same IPO fre-
quency.
Table 3. UART Baud Rate per IPO Index
IPO Index System Clock (MHz)
UART Baud Rate
(kbps)
0 11.0592 57.6
1 5.5296 57.6
2 2.7648 57.6
3 1.3824 28.8