ZAURA RF Module Shell
User Manual
UM023502-0911 write
6
write Write registers
Syntax
write ofs data
Example
write 16 aabbccdd
AA BB CC DD D6
The
write command is used to modify one or more ZAURA RF Wire-
less Module registers beginning with ofs. If the data parameter specifies a
single 8-bit value, only register ofs is modified. Otherwise, subsequent
data values will be written to sequential registers.
Altering the contents of the radio registers can disrupt – or even disable
– all communication within the ZAURA RF Wireless cell and cause the
application to stop working properly. The
write command is typically
only used for diagnostic purposes.