Z8018x
Family MPU User Manual
42
UM005003-0703
To avoid address conflicts with external I/O, the Z8X180 internal I/O
addresses can be relocated on 64-byte boundaries within the bottom 256
bytes of the 64KB I/O address space.
I/O Control Register (ICR)
ICR allows relocating of the internal I/O addresses. ICR also controls
enabling/disabling of the IOSTOP mode.
I/O Control Register (ICR: 3FH)
Bit 76543210
Bit/Field IOA7 IOA6 IOSTP —————
R/W R/W R/W R/W
Reset 0 0 0
R = Read W = Write X = Indeterminate ? = Not Applicable
Bit
Position Bit/Field R/W Value Description
7
6 IOA7:6 R/W IOA7 and IOA6 relocate internal I/O as depicted in
Figure . The high-order 8 bits of 16-bit internal I/O
addresses are always 0. IOA7 and IOA6 are cleared to 0
during RESET.
5 IOSTP R/W IOSTOP mode is enabled when IOSTP is set to 1.
Normal. I/O operation resumes when IOSTP is reset to 0.